CLINICAL LAB DEVICES - EUROTAJ TG-9602 Microplate Reader
Specifications - Measurement System :8-Channel optical system
- Measurement Range : 0.001~3.000Abs
- Photometric Accuracy :±0.01Abs (0.001~1.500Abs
- Repeatability : <±0.5% (0.001~1.500Abs)
- Stability : < 0.005Abs
- Linearity :< ±1% (0.001~1.500Abs)
- Filters :Standard:4 filters (405,450,492,630nm), Totally 7 filters can be installed
- EUROTAJ TG-9602A Microplate Reader
Specifications - Measurement System :2-Channel optical system
- Measurement Range : 0.001—3.500Abs
- Photometric Accuracy : ±1% or ±0.001Abs
- Repeatability : < ±0.5%
- Stability : < 0.005Abs
- Linearity : < ±1%
- EUROTAJ TG-2018 Biochemistry Analyzer
Specifications - Wavelength Range : 340nm~750nm
- Measurement Range : 0.001~3.000Abs
- Precision : ±0.001Abs
- Repeatability : ≤0.005Abs
- Linearity : ≤±1%
- Cross-contamination : ≤1%
- Temperature Accuracy : ±0.1°C
- Test Temperature : 25°C,30°C, 37°C
- Test Method : end-point, kinetic, two-point , standard
curve and simple/double wavelength exam - Colorimetric Pool : Titanium alloy
- Reagent : 400μl~800μl Match all kinds of reagent (WITH INTERNAL PRINTER)
- Sample volume : 20~50μl
- Display : Photometric absorbance, density, active unit, and normal parameters
- EUROTAJ TG-2018G Biochemistry Analyzer
Specifications - Wavelength Range: 340nm~750nm
- Measurement Range: 0.000~3.000Abs
- Repeatability: ≤0.005
- Linearity: ≤1.0%
- Temperature Accuracy: ±0.2°C
- Colorimetric Pool: Titanium alloy
Test Method: Absorbency, End-poit, Kinetic,Two-point, Standard Curve, Control Tube, Factor - 7.5" colorful touch screen
- EUROTAJ TG-9620 Computerized Microplate Washer
Specifications - Washing Head : 8 or 12 channels
- Applicable Microplate : 96 or 48 wells microplate
- Washing Times Option : 1~9 presettable
- Washing Rows Option : 1~12 presettable
- Soak Time : 1~3600s
- Residual Volume : <3μl/well
- EUROTAJ TG-1688 Urine Chemistry Analyzer
Specifications - Test items : GLU,BIL,KET,SG,BLO,PRO,URO,NIT and LEU
- Working wavelength : 557nm, 610nm and 660nm
- Test speed of single step running mode : 60/h
- Test speed of continuous running mode : 210/h
- Data storage : no more than 100 samples
- Printer : internal high-speed thermal printer
- User Information : year, month, day, week, time, sample number and sample code
- EUROTAJ TG-2048B Two-channel Blood Coagulation Analyzer
Specifications - Number of Channels : 2,37°C±0.2°C
- Reagent Storage : 4
- Sample Preparation Positions : 6, 3 with timer
- Reagent Volume : 100μl
- Stray : ≤1%
- Interchannel Error : ≤3%
- Linearity Error : ≤1%
- EUROTAJ TG1000B Electrolyte Analyzer
Specifications - It can measure the concentrations of K+, Na+ , Cl- and Ca++ and
pH values - Applies ISE (Ion Selection Electrode), which gives the instrument the advantages of minimum maintenance, easy assembly and disassembly, as well as stable and reliable measurements
- Working Modes
- Normal mode: automatic calibration; this mode adapts to large and middle scale hospital with large sample volume; sleep functions which can save reagent
- Saving mode: 24 hours reagents consumption is only 7ml when it does not measure. This mode. adapts to hospital with small sample volume.
- Each test channel can be closed separately, So it is convenient to do emergency measurement.
- 110mm×60mm LCD display, automatic screensaver, friendly interface, easy to operate
- Mini thermal printer can print repeatedly at any moment. It is convenient to feed paper. And the print is very clear.
- Revising datas automatically to ensure the accuracy of data.
- It can save1500 test results, data will not be lost even if the power is cut off. Users can inquire or print at any moment.
- The instrument is equipped with a RS232 serial port, which can be connected to computer. It may collect, manage and print measure result by relevant software.
- It has electrode-checking function. Users can do corresponding maintenance according to checking result
- Exempt of routine maintenance, this greatly lighten the burden of operators; In-side software self-checking can suggest users eliminate the malfunction in time.
- Advanced and reliable fluid position examination technology can save reagent
- Adopt built-in operating system leads to a reliable performance.
- Users can modify each setting to meet different requirements
- The quality-control inspecting function can track the accuracy of the instrument.
| Test Object | Linearity | Repeatability (Cv) | Stability | Accuracy | | K+ | ±0.3mmol/L | ≤1.0 % | ±0.2mmol/L/h | ±0.3mmol/L | | Na+ | ±3.0mmol/L | ≤1.0 % | ±0.2mmol/L/h | ±3.0mmol/L | | Cl- | ±3.0mmol/L | ≤1.0 % | ±2.0mmol/L/h | ±3.0mmol/L | | Ca++ | ±0.2mmol/L | ≤2.0 % | ±0.2mmol/L/h | ±0.2mmol/L | | pH | -- | ≤1.0 % | ±0.02/h | -- |
BLOOD ANALYZER | - EUROTAJ TG6000 Auto Hematology Analyzer
Specifications - ITest Items
WBC, LY#, MO#, GR#, LY%, MO%, GR%, HGB, RBC, HCT, MCV, MCH, MCHC, RDW—CV, RDW—SD, PLT, PCT, MPV, PDW, WBC Histogram, RBC Histogram, PLT Histogram Background Count - WBC: ≤0.3×109/L RBC: ≤0.03×1012/L HGB: ≤1g/L PLT: ≤10×109/L
- Linearity
Test Item Test Range Allow Difference of Linearity WBC 0~6.0×109/L ±0.3×109/L 6.0~99.9×109/L ±5% RBC 0~0.99×1012/L ±0.05×1012/ L 1.0~9.99×1012/L ±5% HGB 0~99 g/L ±2g/L 100~300 g/L ±2% PLT 0~99×109/L ±10×109/L 100~999×109/L ±10% - Repeatability
Test Item CV (%) Teat Range WBC ≤2.0 7.0~15.0×109/L RBC ≤0.5 3.5~6.0×1012/L HGB ≤1.5 110~180g/L PLT ≤4.0 150~500×109/L MCV ≤0.5 80~110fL - Sample Volume
Twig blood: 20μl - Dilution Ratio
WBC/HGB: 1:500 RBC/PLT: 1:50000 - Interfaces
RS232 joint, USB, PS2, Parallel port - Test Speed
60 samples/hours Continuous Work Time >8h
- EUROTAJ TG9030B Semi-automatic Hematology Analyzer (18 Parameters)
Specifications - Test Items : 18 parameters: RBC, HGB, WBC, LY#, MO#,GR#, LY%, MO%, GR%, HCT, MCV, MCH, MCHC, RDW, PLT, MPV, PCT, PDW
- Linearity Range : RBC: 1.00~9.99×1012/L HGB: 20g/L~200g/L
- WBC: 0.50~99.0×109/L , PLT: 50~999×109/L
- Precision (CV) : RBC: ≤2.5%
HGB: ≤1.5% WBC: ≤3.5% LY%:≤6% MO%:≤12% GR%:≤6% MCV:≤2% PLT:≤5% MPV:≤3% - Dilution Ratio : WBC / HGB 1:500, RBC / PLT 1:50000
- Sample volume : Periphery/whole blood: 20μl
- Reagents 10kgs 1. HB Non-cyanogen Hemolysin 2×15ml
2. HB Diluent 4L 3. HB Washing Solution 4L
- EUROTAJ TG9030C Semi-automatic Hematology Analyzer(14 Parameters)
Specifications - Testing Items : RBC, HGB, HCT, MCV, MCH, MCHC, RDW,
WBC, LY#, MO#,GR#, LY%, MO%, GR%, White Blood Cell Histogram, Red Blood Cell Histogram - Linearity Range : RBC: 1.00~9.99×1012/L
HGB: 20g/L~200g/L , WBC: 0.50~99.0×109/L - Precision (CV) : RBC: ≤2.5%, MCV: ≤2.0%, HGB: ≤1.5%, WBC: ≤3.5%
- Principle: Blood corpuscle count-impedance, HGB--- colorimetric method with 540nm wavelength
- Display : LCD directly displays the working status, testing items, results and histogram
- Sample Volume : Periphery blood 20μl
- Dilution Ratio : WBC/HGB 1:500, RBC 1:50000
- Printer : Built-in stylus printer Print the testing parameters directly
- Reagents 10kgs 1. HB Non-cyanogen Hemolysin 2×15ml
2. HB Diluent 4L 3. HB Washing Solution 4L
- EUROTAJ TG-2048B Two-channel Blood Coagulation Analyzer
Specifications
- Number of Channels : 2,37°C±0.2°C
- Reagent Storage : 4
- Sample Preparation Positions : 6, 3 with timer
- Reagent Volume : 100μl
- Stray : ≤1%
- Interchannel Error : ≤3%
- Linearity Error : ≤1%
- EUROTAJ TG5000 Hematology Analyzer
| Test Items | WBC, LY#, MO#, GR#, LY%, MO%, GR%, HGB, RBC, HCT, MCV, MCH, MCHC, RDW—CV, RDW—SD, PLT, PCT, MPV, PDW, WBC Histogram, RBC Histogram, PLT Histogram | Performance Index | Test Item | Linearity Range | Precision | | WBC(×109/L) | 0.0-99.9 | CV≤2% (4.0-10.0×109/L) | | RBC (×1012/L) | 0.00-9.99 | CV≤1.5% (2-6.0×1012/L) | | HGB (g/L) | 20-200 | SD≤3g/L (30-100)g/L CV≤1.5% (101-200)g/L | | MCV (fL) | 40.0-150 | CV≤0.5% (80.0-100fL) | | PLT (×109/L) | 0.0-999 | CV≤4.0% (100-500×109/L) | | Repeatability | Test Item | CV (%) | Test Range | | WBC | ≤2 | 4.0~10.0×109/L | | RBC | ≤1.5 | 3.5~6.0×1012/L | | HGB | SD≤3g/L CV≤1.5% (101-200)g/L | 30~100g/L 101~200g/L | | PLT | ≤4 | 100~300×109/L | | MCV | ≤0.5 | 80~110fL | | Sample Volume | Twig blood: 20μl | | Dilution Ratio | WBC/HGB: 1:500RBC/PLT: 1:50000 | | Interfaces | RS232 joint | | Continuous Work Time | >8h |
- EUROTAJ TG-1 Hemoglobin Meter(Vertical/Horizontal)
Specifications - Test Item : Hemoglobin(HGB)
- Test Method : High ferricyanide
- Wavelength : 540nm
- Displayed Number : Three-digit number
- Measurement Range : 0~200g/L
- Dilution Ratio : 1:251 1:501
- Sample Volume : 2mL±10%
- Test Time : ≤8s
- Linearity Error : <100g/L±3g/L , <100-200g/L±3%
- Coefficient of Variation : ≤2%
- Power Supply : AC220V±10%;50Hz±2%
- Input Power : 10W
- Net Weight : 2.5kg
- Sustained Operation : >8 hour
- Stability : 3g/L 0.5h
X-RAY SERIES - EUROTAJ TG160 High Frequency X-ray Radiograph System (200mA)
Specifications - Power Output: 15KW
- Inverter Frequency : 40kHz
- X-Ray Tube : XD56-5 17/130
Small focus: 0.3 Large focus: 0.6 Thermal capacity: 212kJ (300 KHU) - The speed of the rotary anode: 3000rpm
- Tube Voltage: 40~125kV
- Tube Current :200mA
mAs: 1~360mAs - Bucky grid : Grid density 103L/INCH; Grid ratio:10:1
Focus distance:150cm Stationary 18"×18"(import) - Power supply : 220V 50Hz, Capacity: ≥16kW
- Operation method: graphic remote-control LCD touch screen
and wireless remote-control exposure (Optional: control box of graphic remote-control LCD touch screen)
- EUROTAJ TG102 Mobile X-ray Equipment
Specifications - Power Output : 2.96KW
- X-Ray Tube : Fixed anode
- Commute Method : Full wave commutation
- Tube Voltage : 40~90KV
- Tube Current: 50~90KV 15mA
50~90KV 30mA 40~80KV 50mA - Exposure Time : 50~90KV 15mA 0.1~6.3s
50~90KV 30mA 0.1~6.3s 40~80KV 50mA 0.1~1.5s - Power Supply : 110V±10% 60Hz
inner-resistance≤0.1Ω 4KW - Operation Method : Wire /Wireless control
- Packing Details : 1240mm×750mm×1460mm
N.W.150kgs G.W.210kgs
- EUROTAJ TG101A High Frequency Mobile X-ray Equipment (63mA)
Specifications - Power Output : 3.5KW
- Frequency : 40KHz
- X-Ray Tube : Fixed anode
- focus : 1.5mm
- Tube Voltage : 40~110KV (interval 1KV)
- Tube Current : 40~49KV 63mA 1~125 mAs
50~59KV 56mA 1~110 mAs 60~69KV 45mA 1~90 mAs 70~79KV 40mA 1~80 mAs 80~89KV 36mA 1~71 mAs 90~99KV 32mA 1~63 mAs 100~110KV 20mA 1~40 mAs - mAs : 1.0~125 mAs (45 steps)
- Power Supply : 220V±10℅ 50Hz, inner-resistance≤1.0Ω
- Operation Method : Wire/Wireless control
- Packing Details : 1240mm×900mm×1460mm
N.W. 150kgs G.W.210kgs
- EUROTAJ TG101B High Frequency Mobile X-ray Equipment(63mA)
Specifications
- EUROTAJ TG101C High Frequency Mobile X-ray Equipment (100mA)
Specifications - Power Output: 5.0KW
- Frequency: 40KHz
- X-ray Tube: Fixed anode
Focus 1.5mm - Tube Voltage: 40~110KV (interval 1KV)
- Tube Current: 40~49KV 100mA 1~180 mAs
50~59KV 77mA 1~140 mAs 60~69KV 64mA 1~125 mAs 70~79KV 55mA 1~110 mAs 80~89KV 49mA 1~100 mAs 90~99KV 44mA 1~90 mAs 100~110KV 32mA 1~80 mAs - mAs: 1.0~125 mAs (43 steps)
- Power Supply:220V±10% 50Hz , inner-resistance≤1.0Ω
- Operation Method: Wire/Wireless control
- EUROTAJ TG112 High Frequency Mobile X-ray C-arm System
Specifications Fluoroscopic Capacity - Max rated capacity : Tube Current 4mA, Tube Voltage 110kV
- Automatic Fluoroscopy : Tube Voltage:40kV~110kV adjust automatically
- Tube Current : 0.3mA~4mA set manually
- Manual Fluoroscopy : Continuous Tube Voltage:40kV~110kV
- Continuous Tube Current : 0.3mA~4mA
- Pulse Fluoroscopy : Continuous Tube Voltage 40kV~110kV
Continuous Tube Current 4.1mA~8mA Photography Capacity - Max rated capacity : 3.5 KW
- Tube Voltage and Current Combination : 40kV~49kV 1 ~125 mAs
50kV~59kV 1 ~110 mAs, 60kV~69kV 1 ~90 mAs 70kV~79kV 1 ~80 mAs, 80kV~89kV 1 ~71 mAs 90kV~99kV 1 ~63 mAs,100kV~110kV 1 ~40 mAs X-ray Tube - X-ray Tube Special for High Frequency Fixed anode X-ray tube with 2 foci: Large focus: 1.5mm, small focus: 0.6mmInverter Frequency: 40KHzThermal capacity: 30KJ (40HU)
VideoSystem - Image Intensifier : Image Intensifier made by TOSHIBA (9″~6″~4.5″)
- CCD Vidicon: Import CCD Vidicon with ultra-low luminosity
- Monitor : Horizontal 1000 lines and vertical 800 lines, Bandwidth : 12.5MHz, Image/sec : 25
- CCU(central control) : Recursive Filter: K=8, 7 images storage, image upright, image overturn,positive & negative image;LIH(last image freeze, and OSD(monitor display
Structure - Direction wheel: ±90°revolution,can change the moving direction of the unit
- Ascending & Descending Range of Pillar : ≥400mm
- C-arm: Forward and Backward Movement: 200mm, Revolution around Horizontal Axis: ±180°, Revolution around Vertical Axis : ±15, Slip on orbit: 120°(+90°~ -30°)
|
|